15. SETTING-OUT LINE
• It is also possible to perform setting-out line measurement when [S-O LINE] on
the Meas mode screen.
Allocating [S-O LINE]:"24.2 Allocating Key Functions".
15.2

Setting-out Line Point

Setting-out line point measurement can be used to find the required point
coordinate by inputting the length and offset based on the baseline.
• Before performing setting-out line point, the baseline must be defined.
1st Pt.
PROCEDURE
1. Select "Point" in <Set-out line>
2. Press [EDIT].
Set the following items.
(1) Length: Distance along the
baseline from the first point to
the position at which a line
extending from the required
point intersects the baseline at
right angles (X direction).
(2) Offset: Distance from the
required point to the position
at which a line extending from
the required point intersects
the baseline at right angles (Y
direction).
70
Y direction
X direction
Length
Offset
Required point
Baseline
S e t - o u t l i n e
P o i n t
L i n e
S e t - o u t l i n e
3 . 6 7 8
L e n g t h
1 . 4 5 6 m
O f f s e t
2nd Pt.
m
OK
EDIT