13.2 Setting Instrument Station Coordinate with resection measurement

Resection is used to determine the coordinates of an instrument station by performing multiple measurements
of points whose coordinate values are known. Registered coordinate data can be recalled and set as known
point data. Residual of each point can be checked, if necessary.
Entry
Coordinates of known point
Observed horizontal angle
Observed vertical angle
Observed distance
• All the N, E, Z or only Z data of an instrument station is calculated by measuring the known points.
• Coordinate resection measurement overwrites the N, E and Z data of the instrument station, but height
resection does not overwrite N and E. Always perform resection measurement in the sequence described in
"13.2.2 Coordinate Resection Measurement" and "13.2.4 Height Resection Measurement".
• Input known coordinate data and calculated instrument station data can be recorded in the current JOB.
"29. SELECTING/DELETING A JOB"
13.2.1 Observation setting
Perform observation setting prior to resection measurement.
1. Select "Occ. Orien.".
2. Press [RESEC].
Output
: (Xi, Yi, Zi)
Station point coordinates
: Hi
: Vi
: Di
49
13. COORDINATE MEASUREMENT
: (X0,Y0, Z0)
Coord.
Occ.Orien.
Observation
EDM
0.000
N0:
0.000
E0:
<Null>
Z0:
PT
PNT-001
HI
1.200m
LOAD
BS AZ
BS NEZ RESEC