If the cause cannot be located in the steps above and the problem persists, record the above
information, and contact your local sales agent.
Table 21 Router status LED description
LED
PWR1 (red/green)
PWR2 (red/green)
FAN (red/green)
ALM (red)
RUN (green)

FIP module failure

If the RUN LED of the FIP module is off, it indicates that the FIP module is powered off or faulty.
To troubleshoot the FIP module failure:
Check whether the router is powered on.
1.
If the router is powered on, check whether the FIP module is plugged in a right slot.
2.
If the FIP module is plugged in a right slot, it indicates that the FIP module is faulty. Contact your
3.
local sales agent.

Power module failures

If the router cannot be powered on and the power LED on the front panel is off, it indicates that the
power module is faulty.
To troubleshoot the power module failure:
Check whether the power switch is turned on.
1.
Check whether the power cables of the router are firmly connected.
2.
Check whether the switch of the power source is turned on.
3.
Check whether the power cord is damaged.
4.
Status
Off
Steady green
Steady red
Off
Steady green
Steady red
Off
Steady green
Steady red
Off
Steady red
Flashing fast at 8 Hz
Off
Flashes at 1 Hz
Flashes at 8 Hz
59
Remarks
The power module is not in position.
The power module is supplying power properly.
No power is input or the power module is faulty
when PWR2 is operating properly.
The power module is not in position.
The power module is supplying power properly.
No power is input or the power module is faulty
when PWR1 is operating properly.
No power is input or the fan tray is not is position.
The fan tray is operating properly.
The fan tray is faulty.
The system is operating properly and there is no
alarm.
A fault has occurred. In this state, check the
system log immediately.
The system is seriously faulty. An immediate
action is needed.
No power is input or the router is faulty.
The router is operating properly.
The router is loading software or has not started.