Displaying the electrical label information of a module

Use the display device manuinfo command to display the electrical label information of the module
in each slot.
Electrical label information is also called permanent configuration data or archive information, which
includes the module name, serial number, MAC address, and vendor name.
<Sysname> display device manuinfo
Slot 0:
DEVICE_NAME:SR6602-X2
DEVICE_SERIAL_NUMBER:NONE
MAC_ADDRESS:NONE
MANUFACTURING_DATE:2011-12-12
VENDOR_NAME:H3C
Slot 1:
DEVICE_NAME:RT-FIP-20
DEVICE_SERIAL_NUMBER:NONE
MAC_ADDRESS:NONE
MANUFACTURING_DATE:2011-12-12
VENDOR_NAME:H3C
Use the display device manuinfo slot slot-number command to display the electrical label
information of the module in the specified slot.
<Sysname> display device manuinfo slot 0
Slot 0:
DEVICE_NAME:SR6602-X2
DEVICE_SERIAL_NUMBER:NONE
MAC_ADDRESS:NONE
MANUFACTURING_DATE:2011-12-12
VENDOR_NAME:H3C
Table 13 Output description
Field
Slot 0
DEVICE_NAME
DEVICE_SERIAL_NUMBER
Description
Module model. The value NONE indicates that no module is present in the slot.
Running status of the module:
Absent—No module is present in the slot.
Fault—The module in the slot is booting, or the module fails and cannot
boot properly.
Normal—The module in the slot is a service module and is operating
properly.
Maximum number of interfaces that the module supports.
Description
Router or interface module slot
Router or module type
Router or module serial number