Disk Drive Modules in Use
1. If you are removing the disk drive module under concurrent maintenance (see
"Concurrent Maintenance" on page 137), first ensure that no hdisk is using the pdisk
(disk drive module) that you want to remove. Use the Configuration Verification
service aid (see the chapter about service aids in the User's Guide and
Maintenance Information manual for your SSA adapter) to determine whether the
pdisk is related to an hdisk.
2. If the pdisk is related to an hdisk that is a RAID array, go to step 3.
If the pdisk is related to an hdisk that is not a RAID array, make that hdisk
unavailable to the using system, and go to step 6 on page 150.
Note: Making an hdisk unavailable is usually a responsibility of system
If the pdisk is not related to an hdisk, go to step 6 on page 150.
3. For fast path, type smitty redssaraid and press Enter.
Otherwise:
a. Select Change Member Disks in an SSA RAID Array from the SSA RAID
b. Select Remove a Disk from an SSA RAID Array.
4. A list of arrays is displayed in a window:
Move cursor to desired item and press Enter.
Select the SSA RAID array from which you are removing the disk drive module.
administration.
Array menu.
Change Member Disks in an SSA RAID Array
Remove a Disk from an SSA RAID Array
Add a Disk to an SSA RAID Array
Swap Members of an SSA RAID Array
--------------------------------------------------------------------------
|
|
| Move cursor to desired item and press Enter.
|
|
hdisk3
095231779F0737K good
|
hdisk4
09523173A02137K good
|
| F1=Help
F2=Refresh
| F8=Image
F10=Exit
| /=Find
n=Find Next
--------------------------------------------------------------------------
SSA RAID Array
3.4G
RAID-5 array
3.4G
RAID-5 array
F3=Cancel
Enter=Do
Appendix A. Additional Information for RISC Systems
|
|
|
|
|
|
|
|
|
|
269