Displays also VPD information.
-i
Displays the enclosure identifier (as shown in the operator panel, if present).
-r
Displays "RPO present TRUE/FALSE" (RPO is the remote power-on control).
-b [card]
Displays the status of the bypass cards. If no parameters are given, the status
for all the bypass cards is displayed. Valid values for the [card] parameter are:
1, 4, 5, 8, 9, 12, 13, 16.
-t [threshold]
Displays all the temperature thresholds, or only the specified temperature
thresholds. The valid values for the [threshold] parameter are:
lowarn
The low-temperature warning threshold.
locrit
The low-temperature critical threshold.
hiwarn
The high-temperature warning threshold.
hicrit
The high-temperature critical threshold.
-a
Displays the ambient temperature of the enclosure and temperature threshold
statuses.
-f [fan] Displays the status of all the fans, or of only the specified fans. Valid values for
the [fan] parameter are: 1, 2, 3, and so on.
-d [drive_bay]
Displays the status of all the disk drive bays (slots), or of only the specified
disk drive bays. Valid values for the [drive_bay] parameter are: 1, 2, 3, and so
on.
-p [PSU]
Displays the status of all the power supply assemblies, or of only the specified
power supply assemblies. Valid values for the [PSU] parameter are 1, 2.
-o
Displays the status of the operator panel.
-c
Displays the status of the controller card.
-I ID[-U]
Modifies the enclosure ID. The ID must be a four-character alphanumeric
string. The optional -U flag causes the object data manager (ODM) to be
updated to show the change.
-B mode
Modifies all bypass cards to the given mode.
Appendix A. Additional Information for RISC Systems
267