Executing the fan test via ServerView Operations Manager
▶ Open the ServerView Operations Manager and log in.
▶ Under Administration select Server Configuration.
▶ In the hierarchy tree of the Server list tab, select the server to be
configured.
▶ In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking GO.... In the left-hand section of
the window, the Configuration tab is being activated.
▶ In the navigation area of the Configuration tab, select Other Settings.
▶ Under Daily Fan Test, set the daily fan test time to a few minutes from the
current time. (Ensure to note down your previous setting.)
▶ Click Save Page.
The fan test will be started at the specified time.
▶ After the fan test is complete, restore the time setting to its initial value and
click Save Page.
In case of maintenance done by Fujitsu engineers in Japan:
Executing the fan test via Chassis ID Prom Tool
Please follow the instructions provided separately.
5.2.6

Updating Server View RAID Manager

For the spare parts of the product compatible parts equal to the original parts
might be used. If an old version of the ServerView RAID Manager is used, the
SSD life monitoring function does not work correctly after replacement. Please
always use the latest version of the ServerView RAID Manager.
https://www.fujitsu.com/fts/support/
For Japan:
https://www.fujitsu.com/jp/products/computing/servers/primergy/downloads/
CX400 M6
Upgrade and Maintenance Manual
Basic software procedures
95