Shutting Down The Server - Fujitsu PRIMERGY CX400 M6 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Possibilities to get more information about the defective component
– Checking the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
For more information, see the "ServerView System Monitor" user
guide.
– Checking the System Event Log (SEL), see
System Event Log (SEL)" on page
– Checking the indicators on the components, see
indicators" on page
4.2

Shutting down the server

CAUTION
For more information, see
This step is only required when upgrading or replacing non-hot-plug
components.
▶ Inform the system administrator that the server will be shut down and put
offline.
▶ Terminate all applications.
▶ Perform the required procedures described in the preliminary steps of each
upgrade or maintenance task.
▶ Shut down the server.
If the system is running an ACPI-compliant operating system (OS),
pressing the On/Off button will perform a graceful shutdown.
Power button override
The server node can be switched off (hard power off) by holding
down the On/Off button (approximately 4 - 5 seconds). However, if
you turn off the power in this way, the system will turn on
automatically after a few seconds.
CX400 M6
91.
198.
"Important information" on page
Upgrade and Maintenance Manual
Basic hardware procedures
"Viewing and clearing the
"Connectors and
25.
41