Basic hardware procedures
▶ Remove the stud (1) and then remove the shift bracket.
Required tool:
For the stud: Hexagon screw driver SW7, flat-head screw driver.
For the other screws: Phillips PH2 / (+) No. 2 screw driver.
This only applies if the target chassis is not using the CMA. When using
the CMA, do not remove the shift bracket.
4.8.4

Sliding the server enclosure into the rack

When not using a CMA
Figure 34: Mounting the server enclosure into the rack (B)
▶ Push the server enclosure into the rack.
▶ When the server enclosure is stopped, push the locking latch (1) on both
sides and push the server enclosure into the rack again (2).