Fc 301 Vs. Fc 302 Control Principle - Danfoss VLT AutomationDrive FC 301 Series Design Manual

Hide thumbs Also See for VLT AutomationDrive FC 301 Series:
Table of Contents

Advertisement

Basic Operating Principles

3.6.2 FC 301 vs. FC 302 Control Principle

FC 301 is a general purpose adjustable frequency drive for variable speed applications. The control principle is based on
Voltage Vector Control (VVC
3
3
FC 301 can handle both asynchronous and PM motors.
The current sensing principle in FC 301 is based on current measurement in the DC link or motor phase. The ground fault
protection on the motor side is solved by a de-saturation circuit in the IGBTs connected to the control board.
Short-circuit behavior on FC 301 depends on the current transducer in the positive DC link and the desaturation protection
with feedback from the three lower IGBT's and the brake.
L1 91
L2 92
L3 93
Figure 3.4 Control Principle FC 301
FC 302 is a high performance adjustable frequency drive for demanding applications. The adjustable frequency drive can
handle various kinds of motor control principles such as U/f special motor mode, VVC
FC 302 is able to handle permanent magnet synchronous motors (brushless servo motors) as well as normal squirrel cage
asynchronous motors.
Short-circuit behavior on FC 302 depends on the three current transducers in the motor phases and the desaturation
protection with feedback from the brake.
L1 91
L2 92
L3 93
Figure 3.5 Control Principle FC 302
20
Design Guide
plus
).
Load sharing +
89(+)
R inr
88(-)
Load sharing -
Load sharing +
89(+)
R inr
88(-)
Load sharing -
P 14-50 R Filter
Rev. 2014-04-04 All rights reserved.
Inrush
De-saturation protection
plus
LC Filter +
(5A)
Inrush
LC Filter -
(5A)
R+
Brake
82
Resistor
R-
81
U 96
V 97
M
W 98
Drive
Control
Board
or Flux Vector motor control.
R+
Brake
Resistor
82
R-
81
U 96
V 97
M
W 98