Danfoss VLT AutomationDrive FC 301 Series Design Manual page 166

Hide thumbs Also See for VLT AutomationDrive FC 301 Series:
Table of Contents

Advertisement

Options and Accessories
11.2.2 VLT
The encoder module can be used as feedback source for
closed-loop flux control (1-02 Flux Motor Feedback Source)
as well as closed-loop speed control (7-00 Speed PID
Feedback Source). Configure encoder option in parameter
group 17-** Feedback Option.
Used for
VVC
Flux Vector Speed control
Flux Vector Torque control
Permanent magnet motor
Supported encoder types:
Incremental encoder: 5 V TTL type, RS-422, max. frequency:
410 kHz
Incremental encoder: 1 Vpp, sine-cosine
®
Hiperface
SICK)
EnDat encoder: Absolute and Sine-Cosine (Heidenhain)
Supports version 2.1
SSI encoder: Absolute
NOTICE!
Incremental encoders are not recommended for use with
11
11
PM motors due to risk of wrong polarity.
NOTICE!
It is strongly recommended to always supply the
encoder through the MCB 102. It shall be avoided to use
external power supply for the encoder.
Encoder monitor:
The 4 encoder channels (A, B, Z and D) are monitored,
open and short circuit can be detected. There is a green
LED for each channel which lights up when the channel is
OK.
164
®
Encoder Option MCB 102
plus
closed-loop
Encoder: Absolute and Sine-Cosine (Stegmann/
Design Guide
NOTICE!
The LEDs are only visible when removing the LCP.
Reaction in case of an encoder error can be selected in
17-61 Feedback Signal Monitoring: [0] Disabled, [1]
Warning or [2] Trip.
When the encoder option kit is ordered separately, the
kit includes
The encoder option does not support FC 302 adjustable
frequency drives manufactured before week 50/2004.
Min. software version: 2.03 (15-43 Software Version)
Rev. 2014-04-04 All rights reserved.