9.6
STOPPING & STARTING
The compressor will automatically STOP if the temperature rise for any compression stage reaches a
pre-set value, determined for safe, reliable operation, or should the oil pressure fall below a minimum
pre-set pressure.
The compressor can be STOPPED manually by depressing the EMERGENCY STOP button.
When the compressor has stopped by fault indicating too high air temperature, low oil pressure or
Emergency Stop, the starter fault circuit must be reset before starting again.
In the case of EMERGENCY STOP, the latch button must also be reset by turning clockwise and fully
extending the button.