PART NUMBERS VARIOUS
PREVENTIVE MAINTENANCE
1)
After installation and initial running in. Record height dimension (H) of each mount.
2)
After a week or 100 hours running time recheck and record dimension (H)
3)
Check this dimension every 3 to 6 months depending on usage i.e. regular usage every 3
months.
Note: This dimension may only change a small amount during the life of the mount
approximately 2mm.
4)
Any oil or paint contact with the rubber mount will affect the life and performance, so keep to a
minimum by regularly cleaning and clearing any contamination from the surrounding area.
5)
Under normal working conditions the life expectancy will be 5 to 8 years.
6)
Temperatures in excess of 75°C and below -30°C will have an adverse effect on the rubber
and will shorten the life expectancy.