Installing an optical drive in the SFF drive chassis
Installing an optical drive in the SFF drive chassis
CAUTION:
CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
Prerequisites
Prerequisites
In the SFF drive chassis, the optical drive installation requires the P06677-B21 optical drive enablement option.
Before you perform this procedure, make sure that you have the following items available:
T-10 Torx screwdriver
T-15 Torx screwdriver
Phillips No. 1 screwdriver
Procedure
Procedure
1. If removed, install the front bezel .
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Remove the media bay blank:
a. Remove the media bay blank screws (callout 1).
Retain all screws for future use.
b. Disengage the media bay blank (callout 2).
c. Remove the media bay blank (callout 3).
Retain the blank for future use.
Installing an optical drive in the SFF drive chassis
101