Installation and Operation Guide SOLECTRIA® PVI 25TL-208, PVI 50TL-480 and PVI 60TL-480
The Running status cycle display include: NoErr (Error information), Pdc(kW), Udc(V), Idc(A), Pac(kW) and
Q(kvar).
If the inverter fails to operate normally, the "FAULT" light will illuminate and the fault menu will be
displayed. Select Current Error and press ENT to access the current faults the inverter has recorded. This
information will show on the LCD screen as shown in the Figure 5-6.
6. Menu Functions
LCD displays "Main user interface" when the inverter is in operation mode. Press ESC in this interface to escape
the default interface and to enter the main operation interface. The main operation interface is shown in Figure
6-1.
DOCR-071030-A (10/7/2022)
Figure 5-5 Normal Operation Status
INFO ✔
Current Error
Date
Time
2015/10/22 12:20:08
2015/10/22 12:20:08
2015/10/22 12:20:08
2015/10/22 12:20:08
2015/10/22 12:20:08
Figure 5-6 Fault Information Interface
Main Menu
Measurement Data Setting
Power On/Off
History Record
Device Information
Figure 6-1 Main Menus on the LCD
Fault
ArcboardErr
Fault0040
Fault0040
Fault0040
Fault0040
P1/1