YASKAWA Solectria PVI 25TL-208 Installation And Operation Manual page 83

Commercial 1000vdc string inverters
Hide thumbs Also See for Solectria PVI 25TL-208:
Table of Contents

Advertisement

Installation and Operation Guide SOLECTRIA® PVI 25TL-208, PVI 50TL-480 and PVI 60TL-480
N
e
g
1.3
a
l t
o
V
1.25
1.2
d
t e
* r a
1.15
1.1
1.05
1
Table 6-6 LVRT Parameter List with Setup Lower Limit, Default, and Upper Limit
Parameter
DESCRIPTION
name
LVRTVOLT
Threshold value of
(1,2) (%)
Low voltage ride
through (1st & 2nd
LVRTTIME
Time of Level Low
(1,2) (S)
voltage ride through
(1st & 2nd point)
LVRTVOLT
Threshold value of
(3,4) (%)
Low voltage ride
through (3rd & 4th
LVRTTIME
Time of Level Low
(3,4) (S)
voltage ride through
(3rd & 4th point)
DOCR-071030-A (10/7/2022)
1 2
3
2 4 6 8 10 12 14 16 18 20 22
Figure 6-10 HVRT Curve
MIN
0.00
0.00
point)
0.00
0.00
0.00
0.00
point)
0.00
0.00
4
Through
5,6,7,8
SETUP RANGE
IEEE 1547
DEFAULT
MAX
0.00
100.00
0.00
100.00
0.00
655.00
1.20
655.00
45.00
100.00
45.00
100.00
1.20
655.00
10.50
655.00
Trip
Time/S
RULE 21
MIN
DEFAULT
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1.20
0.00
45.00
0.00
45.00
0.00
1.20
10.50
0.00
Page 83 of 131
MAX
100.00
100.00
655.00
655.00
100.00
100.00
655.00
655.00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solectria pvi 50tl-480Solectria pvi 60tl-480

Table of Contents