Rod Electrode Setup Menu; Open The Rod Electrode Set-Up Menu; Changing Welding Parameters; Exiting The Set-Up Menu - Fronius TransTig 800 Operating Instructions Manual

Table of Contents

Advertisement

Rod electrode setup menu

Open the rod
electrode set-up
menu
Changing weld-
ing parameters
Exiting the set-
up menu
Welding para-
"Minimum" and "maximum" are used for setting ranges that differ according to
meters in the rod
power source, wire-feed unit, welding program, etc.
electrode set-up
menu
HCU
HotStart current
Unit
Setting range
Factory setting
Hti
Hot-current time
Unit
Setting range
Factory setting
To obtain optimum welding results, it will sometimes be necessary to adjust
the hotstart function.
Benefits:
-
-
-
82
Press the Mode button to select the MMA welding mode
1
Press and hold the "Mode" button
2
Press the right parameter selection button
3
The power source is now in the rod electrode set-up menu. The
last welding parameter selected is displayed.
Use the left or right parameter selection button to select the
1
welding parameter that you want to change
Use the adjusting dial to change the welding parameter value
2
Press the Mode button
1
% (of main current I
0 - 200
150
s
0 - 2,0
0,5
Improved ignition, even when using electrodes with poor ignition proper-
ties
Better fusion of the base material in the start-up phase, meaning fewer
cold-shut defects
Largely prevents slag inclusions
)
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents