Working voltage
Striking voltage (U
The arc striking voltage is suitable for manual operation.
Degree of protection
Type of cooling
Insulation class
EMC device class
(in accordance with EN/IEC 60974-10)
Dimensions L/W/H (with handle)
Weight (without handle)
Weight (with handle)
Mark of conformity
MagicWave 2200
Mains voltage
Mains voltage tolerance
Grid frequency
Mains fuse protection (slow-blow)
Mains connection
Primary continuous power (100% D.C.
Cos phi
Welding current range
Welding current at
Open circuit voltage
Working voltage
TIG
Electrode
)
p
1)
TIG
Electrode
10 min/25 °C (77 °F) 40% D.C.
10 min/25 °C (77 °F) 60% D.C.
10 min/25 °C (77 °F) 100% D.C.
10 min/40 °C (104 °F) 35% D.C.
10 min/40 °C (104 °F) 60% D.C.
10 min/40 °C (104 °F) 100% D.C.
TIG
Electrode
2)
)
2)
2)
2)
2)
2)
2)
10.1 - 16.8 V
20.4 -25.6 V
9.5 kV
IP 23
AF
B
A
485 / 180 / 344 m
m
19.1 / 7.1 / 13.6 in.
14.6 kg
30.8 lb.
15 kg
33 lb.
S, CE
230 V
-20% / +15%
50/60 Hz
16 A
No restrictions
3.7 kVA
0.99
3 - 220 A
10 - 180 A
220 A
180 A
150 A
220 A
170 A
150 A
88 V
10.1 - 18.8 V
20.4 - 27.2 V
101