Err | 051
Cause:
Mains undervoltage: The mains voltage has dropped below the lower
limit of the tolerance range (see section "Technical data")
Remedy:
Check the mains voltage
Err | 052
Cause:
Mains overvoltage: The mains voltage has exceeded the upper limit of
the tolerance range (see section "Technical data")
Remedy:
Check the mains voltage
no | IGn
Cause:
"Ignition time-out" function is active; current did not start flowing
before the length of wire specified in the set-up menu had been fed.
The power source safety cut-out has tripped.
Remedy:
Press the torch trigger repeatedly; clean the workpiece surface; if ne-
cessary, increase the time until the safety cut-out is triggered in the
set-up menu: level 2
Err | PE
Cause:
The earth current watchdog has triggered the safety cut-out of the
power source.
Remedy:
Switch off the power source, wait for 10 seconds and then switch it
on again. If you have tried this several times and the error keeps re-
curring, contact After-Sales Service.
Err | IP
Cause:
Primary overcurrent
Remedy:
Contact After-Sales Service
Err | bPS
Cause:
Fault in power module
Remedy:
Contact After-Sales Service
dSP | Axx
Cause:
Fault in the central control and regulation unit
Remedy:
Contact After-Sales Service
dSP | Cxx
Cause:
Fault in the central control and regulation unit
Remedy:
Contact After-Sales Service
dSP | Exx
Cause:
Fault in the central control and regulation unit
Remedy:
Contact After-Sales Service
dSP | Sy
Cause:
Fault in the central control and regulation unit
Remedy:
Contact After-Sales Service
dSP | nSy
Cause:
Fault in the central control and regulation unit
Remedy:
Contact After-Sales Service
no | Arc
Cause:
Arc break
Remedy:
Press the torch trigger repeatedly; clean the surface of the workpiece