TransTig 3000
Mains voltage
MV
Mains voltage tolerance
Grid frequency
Mains fuse protection (slow-blow)
Mains connection
Primary continuous power (100% D.C.
Cos phi
Welding current range (3-phase)
Welding current range (single phase)
Welding current at 3 x 400 - 460 V
Welding current at 3 x 200 - 240 V
Welding current at 1 x 200 - 240 V
Open circuit voltage
Working voltage
Striking voltage (U
The arc striking voltage is suitable for manual operation.
116
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
1)
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
TIG
Electrode
TIG
Electrode
10 min/40 °C (104 °F) 45% D.C.
10 min/40 °C (104 °F) 50% D.C.
10 min/40 °C (104 °F) 100% D.C.
10 min/40 °C (104 °F) 35% D.C.
10 min/40 °C (104 °F) 40% D.C.
10 min/40 °C (104 °F) 100% D.C.
10 min/40 °C (104 °F) 50% D.C.
10 min/40 °C (104 °F) 55% D.C.
10 min/40 °C (104 °F) 100% D.C.
TIG
Electrode
)
p
2)
)
2)
2)
2)
2)
2)
2)
2)
2)
2)
3 x 200 - 240 V
3 x 400 - 460 V
1 x 200 - 240 V
± 10%
50/60 Hz
16 A
32 A
32 A
3)
Z
on PCC
max
= 97 mOhm
5.9 kVA
5.0 kVA
4.3 kVA
0.99
3 - 300 A
10 - 300 A
3 - 220 A
10 - 180 A
300 A
-
240 A
-
300 A
210 A
-
220 A
190 A
85 V
10.1 - 22.0 V
20.4 - 32.0 V
10 kV