Welding current range (3-phase)
Welding current range (single phase)
Welding current at 3 x 400 - 460 V
Welding current at 3 x 200 - 240 V
Welding current at 1 x 200 - 240 V
Open circuit voltage
Working voltage
Striking voltage (U
The arc striking voltage is suitable for manual operation.
Degree of protection
Type of cooling
Insulation class
EMC device class
(in accordance with EN/IEC 60974-10)
Dimensions L/W/H (with handle)
Weight
Mark of conformity
Idle state power consumption at 400 V
Power source efficiency at 300 A / 32.0 V
MagicWave 4000
Mains voltage
106
TIG
Electrode
TIG
Electrode
10 min/40 °C (104 °F) 35% D.C.
10 min/40 °C (104 °F) 40% D.C.
10 min/40 °C (104 °F) 100% D.C.
10 min/40 °C (104 °F) 30% D.C.
10 min/40 °C (104 °F) 35% D.C.
10 min/40 °C (104 °F) 100% D.C.
10 min/40 °C (104 °F) 40% D.C.
10 min/40 °C (104 °F) 50% D.C.
10 min/40 °C (104 °F) 100% D.C.
TIG
Electrode
)
p
2)
2)
2)
2)
2)
2)
2)
2)
2)
3 - 300 A
10 - 300 A
3 - 220 A
10 - 180 A
300 A
-
190 A
300 A
-
180 A
-
220 A
160 A
89 V
10.1 - 22.0 V
20.4 - 32.0 V
10 kV
IP 23
AF
B
A
560 / 250 / 435 m
m
22.0 / 9.8 / 17.1 in.
30 kg
66.14 lb.
S, CE
47.4 W
83%
3 x 400 V