Mains connection
Primary continuous power (100% D.C.
Cos phi
Welding current range
Welding current at
Open circuit voltage
Working voltage
Striking voltage (U
The arc striking voltage is suitable for manual operation.
Degree of protection
Type of cooling
Insulation class
EMC device class
(in accordance with EN/IEC 60974-10)
Dimensions L/W/H (with handle)
Weight
Mark of conformity
Idle state power consumption at 400 V
Power source efficiency at 440 A / 37.6 V
MagicWave 4000
Mains voltage
MV
Mains voltage tolerance
Grid frequency
Mains fuse protection (slow-blow)
Mains connection
Primary continuous power (100% D.C.
108
1)
TIG
Electrode
10 min/40 °C (104 °F) 40% D.C.
10 min/40 °C (104 °F) 45% D.C.
10 min/40 °C (104 °F) 60% D.C.
10 min/40 °C (104 °F) 100% D.C.
TIG
Electrode
)
p
1)
2)
)
2)
2)
2)
2)
2)
)
Restrictions pos-
sible
17.9 kVA
0.99
3 - 500 A
10 - 440 A
500 A
-
440 A
350 A
90 V
10.1 - 30.0 V
20.4 - 37.6 V
9.5 kV
IP 23
AF
F
A
625 / 290 / 705 m
m
24.6 / 11.4 / 27.8 i
n.
58.2 kg
128 lb.
S, CE
40.1 W
86%
3 x 200 - 240 V
3 x 380 - 460 V
± 10%
50/60 Hz
63 / 35 A
Restrictions pos-
sible
13.9 kVA