Fit ferrules to phase conductors and the ground conductor of the mains
3
cable; crimp ferrules with pliers
CAUTION!
Risk of short circuits!
If ferrules are not used, there is a risk of short circuits between the phase
conductors or between phase conductors and the ground conductor.
Fit ferrules to all phase conductors and the ground conductor of the
stripped mains cable.
7
5
Undo the screws (2 x) and clamping
4
nut (size 30) on the strain-relief
device
Insert the mains cable into the
5
strain-relief device
NOTE!
Push the mains cable in far enough to
make it possible to connect the
P E
ground conductor and the phase con-
W 1
V 1
ductors to the block terminal prop-
U 1
8
erly.
Tighten the clamping nut (size 30
6
mm)
Tighten the screws (2 x)
7
Connect the mains cable to the
8
block terminal correctly:
-
Ground conductor (green, or
green with yellow stripes) to
the PE connection
-
Phase conductors to connec-
tions L1 - L3
Re-fit the left side panel of the
9
power source
51