Rod Electrode Setup Menu; Parameters In The Stick Electrode Setup Menu - Fronius Artis 170 Operating Instructions Manual

Table of Contents

Advertisement

Rod Electrode Setup Menu

Parameters in
The following parameters are available through the stick electrode Setup menu:
the stick elec-
trode Setup
menu
HotStart current
1 - 200%
Factory setting: 130%
Starting current duration
0.1 - 2.0 s
Factory setting: 0.5 s
Start ramp
To activate/deactivate the start ramp for the manual metal arc welding ignition
process
on / off
Factory setting: on (activated)
Pulse frequency
for pulse welding with stick electrodes
off / 0.2 - 990 Hz
Factory setting: off
The set pulse frequency is also applied for the lowering current.
The pulsing special indicator illuminates on the control panel if a value for the
pulse frequency has been entered.
Anti-stick
on / off
Factory setting: on