Striking voltage (U
The arc striking voltage is suitable for manual operation.
Degree of protection
Type of cooling
Insulation class
EMC device class
(in accordance with EN/IEC 60974-10)
Dimensions L/W/H (with handle)
Weight (without handle)
Weight (with handle)
Mark of conformity
Idle state power consumption at 230 V
Power source efficiency at 180 A / 27.2 V
MagicWave 2500
Mains voltage
Mains voltage tolerance
Grid frequency
Mains fuse protection (slow-blow)
Mains connection
Primary continuous power (100% D.C.
Cos phi
Welding current range
Welding current at
Open circuit voltage
Working voltage
Striking voltage (U
The arc striking voltage is suitable for manual operation.
Degree of protection
102
)
p
1)
TIG
Electrode
10 min/40 °C (104 °F) 35% D.C.
10 min/40 °C (104 °F) 40% D.C.
10 min/40 °C (104 °F) 100% D.C.
TIG
Electrode
)
p
2)
)
2)
2)
2)
9.5 kV
IP 23
AF
B
A
485 / 180 / 390 m
m
19.1 / 7.1 / 15.4 in.
17.4 kg
38.3 lb.
17.8 kg
39.2 lb.
S, CE
32.3 W
81%
3 x 400 V
± 15%
50/60 Hz
16 A
3)
Z
on PCC
max
= 122 mOhm
4.7 kVA
0.99
3 - 250 A
10 - 250 A
-
250 A
180 A
89 V
10.1 - 20.0 V
20.4 - 30.0 V
10 kV
IP 23