Rod electrode setup menu

Accessing the
Rod electrode
setup menu
Changing weld-
ing parameters
Exiting the Rod
electrode setup
menu
Welding parame-
HCU
ters in the Rod
HotStart current
electrode setup
menu
Unit
Setting range
Factory settings
Hti
Hot-current time
Unit
Setting range
Factory settings
To obtain optimum welding results, it will sometimes be necessary to adjust the HotStart
function.
Benefits
-
-
-
Press the Mode button to select the MMA welding mode
1
Press and hold the Mode button
2
Press the Parameter Selection button (right)
3
The power source is now in the Rod electrode setup menu. The last
welding parameter selected is displayed.
Use the left or right Parameter Selection button to select the param-
1
eter that you want to change
Use the adjusting dial to change the parameter value
2
Press the Mode button
1
%
0 - 200
150
s
0.0 - 2.0
0.5
Improved ignition, even when using electrodes with poor ignition properties
Better fusion of the base material in the start-up phase, meaning fewer cold-shut de-
fects
Largely prevents slag inclusions
71