4.2.2 Feed per Revolution (Synchronous Feed)
M720VW
M system
L system
By issuing the G95 command, the commands from that block are issued directly by the numerical value
following F as the feed rate per spindle revolution (mm/revolution or inch/revolution).
The least command increment and command range of the feed rate designation F are as follows.
[M system]
Metric input
Input
Setting unit
Command
Mode
Command
Address
Minimum
command
unit
Command
range
Inch input
Input
setting unit
Command
Mode
Command
Address
Minimum
command
unit
Command
range
M730VW
M750VW
B(0.001mm)
C(0.0001mm)
Feed per revolution
Feed per revolution
F(mm/rev)
F(mm/rev)
1(=0.001)
1(=0.0001)
(1.=1.0)
(1.=1.0)
0.001 -
0.0001 -
999.999
999.9999
B(0.0001inch)
C(0.00001inch)
Feed per revolution
Feed per revolution
F(inch/rev)
F(inch/rev)
1(=0.00001)
1(=0.000001)
(1.=1.00)
(1.=1.00)
0.00001 -
0.000001 -
99.99999
99.999999
M700V Series Specifications Manual
M720VS
M730VS
M750VS
D(0.00001mm)
Feed per revolution
F(mm/rev)
1(=0.00001)
(1.=1.0)
0.00001 -
999.99999
D(0.000001inch)
Feed per revolution
F(inch/rev)
1(=0.0000001)
(1.=1.00)
0.0000001 -
99.9999999
4 Feed
E(0.000001mm)
Feed per revolution
F(mm/rev)
1(=0.000001)
(1.=1.0)
0.000001 -
999.999999
E(0.0000001inch)
Feed per revolution
F(inch/rev)
1(=0.00000001)
(1.=1.00)
0.00000001 -
99.99999999