4.2.2 Feed per Revolution (Synchronous Feed)
M720VW
M system
△
L system
○
By issuing the G95 command, the commands from that block are issued directly by the numerical value
following F as the feed rate per spindle revolution (mm/revolution or inch/revolution).
The least command increment and command range of the feed rate designation F are as follows.
[M system]
Metric input
Input
Setting unit
Command
Mode
Command
Address
Minimum
command
unit
Command
range
Inch input
Input
setting unit
Command
Mode
Command
Address
Minimum
command
unit
Command
range
M730VW
M750VW
△
△
○
○
B(0.001mm)
C(0.0001mm)
Feed per revolution
Feed per revolution
F(mm/rev)
F(mm/rev)
1(=0.001)
1(=0.0001)
(1.=1.0)
(1.=1.0)
0.001 -
0.0001 -
999.999
999.9999
B(0.0001inch)
C(0.00001inch)
Feed per revolution
Feed per revolution
F(inch/rev)
F(inch/rev)
1(=0.00001)
1(=0.000001)
(1.=1.00)
(1.=1.00)
0.00001 -
0.000001 -
99.99999
99.999999
M700V Series Specifications Manual
M720VS
M730VS
M750VS
△
△
○
○
D(0.00001mm)
Feed per revolution
F(mm/rev)
1(=0.00001)
(1.=1.0)
0.00001 -
999.99999
D(0.000001inch)
Feed per revolution
F(inch/rev)
1(=0.0000001)
(1.=1.00)
0.0000001 -
99.9999999
4 Feed
△
○
E(0.000001mm)
Feed per revolution
F(mm/rev)
1(=0.000001)
(1.=1.0)
0.000001 -
999.999999
E(0.0000001inch)
Feed per revolution
F(inch/rev)
1(=0.00000001)
(1.=1.00)
0.00000001 -
99.99999999
III - 43