4.3.4 Override Cancel
M720VW
M system
L system
By turning on the override cancel external signal, the override is automatically set to 100% for the cutting
feed during an automatic operation mode (tape, memory and MDI).
(Note 1) The override cancel signal is not valid for manual operation.
(Note 2) When the cutting feed override or second cutting feed override is 0%, the 0% override takes
precedence and the override is not canceled.
(Note 3) The override cancel signal is not valid for rapid traverse.
M730VW
M750VW
M720VS
M700V Series Specifications Manual
M730VS
M750VS
4 Feed
III - 49