4.5.4 Run List Program
The user can run the existed list program as needed to enable outputting of cor-
responding waveform sequence by the power supply. Detailed operation steps
are as below:
1. Press [Shift]+[I-set] (Function) to enter function menu interface.
2. Use left and right keys or rotate the knob to select List and press [Enter]
3. Select the desired list program.
4. Select Run List and press [Enter] key to confirm.
5. Use the knob to set Run List to On and press [Enter] key to confirm.
6. Press [On/Off] key to turn the output on.
7. Based on the trigger method, perform the trigger operation. When the trigger
Stop running: During the running of List, you can press [Shift]+[I-set] (Func-
tion) to enter the Function menu and set the Run List as Off to stop running.
Otherwise, the List waveform cannot be edited while the List is running.
4.6 External Analog Quantity Function (Option)
This menu item is used to control the external analog quantity function to enable
or disable. The external analog interface is not the standard-equipped interface
for the power supply.
This series power supply provides a optional DB–25 analog interface(IT-
E1208). The analog interface provides the following capability:
•
•
•
•
•
•
key to enter the set interface of list mode.
•
Method 1: Select Recall List and press [Enter] key. Use knob to select
the desired list program and press [Enter] key to confirm.
•
Method 2: To simplify the operation, you can directly run the list program
after editing it in the Edit List menu item. Skip the step in the Recall List
menu item.
signal is received, the power supply outputs the waveform sequences.
Remote control of output voltage and current
Remote control of output On/Off state
Remote monitoring of output voltage/current measurement and CC/CV
mode
Remote monitoring of output On/Off state, load status and fault status
Clear the instrument malfunction
RS-485 communication interface, please refer to
detailed description about the interface
Copyright © Itech Electronic Co., Ltd.
Functions and Features
2.7.6 RS-485 Interface
for
73
Need help?
Do you have a question about the IT-M3100D Series and is the answer not in the manual?