Powering On The Appliance; Powering On An Oracle Storage Drive Enclosure De3-24 Or De2-24 Disk Shelf - Oracle ZFS Storage DE3-24P Installation Manual

Table of Contents

Advertisement

12

Powering On the Appliance

This section contains power-on procedures for Oracle ZFS Storage Appliance disk shelves
and storage controllers.
Caution:
Do not power on disk shelves and controllers until all other cabling is complete, as
described in
Follow these steps to power on the appliance:
Power on disk shelves using the appropriate procedure:
1.
Power on controllers. See
2.
Use the following procedures to power off the appliance:
Powering Off a Controller
Powering Off a Disk Shelf
Powering On an Oracle Storage Drive Enclosure DE3-24 or
DE2-24 Disk Shelf
Use the following procedure to power on an Oracle Storage Drive Enclosure DE3-24P,
DE3-24C, DE2-24P or DE2-24C disk shelf.
Before You Begin
Ensure you have met the following electrical safety measures before applying power to the
disk shelf:
Provide a suitable power source with electrical overload protection to meet the power
supply input voltage range of 100-240 VAC, 50-60 Hz. The disk shelves are compatible
with 100-120 VAC or 200-240 VAC sources. The power source must not be overloaded
by the total number of disk shelves in the cabinet. At full load, each DE3-24 or DE2-24
draws 707.8W.
The power source must provide a reliable earth connection for each disk shelf and the
cabinet.
Ensure that the power source is easily accessible because the power cord is the main
disconnect device for the disk shelf.
Plug a power cord into each power supply with fan module.
1.
Plug the other end of the power cords into the external power source for the cabinet.
2.
Cabling the
Appliance.

Powering On an Oracle Storage Drive Enclosure DE3-24 or DE2-24 Disk Shelf

Powering On a Sun Disk Shelf
Powering On a
Controller.
12-1