Powering Off A Disk Shelf - Oracle ZFS Storage DE3-24P Installation Manual

Table of Contents

Advertisement

To initiate an emergency shutdown during which all applications and files will be
closed abruptly without saving, press and hold the Power button for at least four
seconds until the Power/OK status indicator on the front panel flashes, indicating
that the storage controller is in standby power mode. To completely remove power,
disconnect the AC power cords from the rear panel of the storage controller.
Related Topics

Powering Off a Disk Shelf

Powering On a Controller
Powering Off a Disk Shelf
If a disk shelf is a part of a storage pool, powering off or removing all SAS chains from
a disk shelf will trigger a kernel panic on the controller(s) to prevent data loss, unless
the disk shelf is part of an NSPF (no single point of failure) data pool. To avoid this,
shut down the controller(s) before decommissioning the disk shelf, as described in
Powering Off a
Place the power supply on/off switches to the "O" off position.
1.
Disconnect the power cords from the external power source for the cabinet.
2.
Related Topics
Powering Off a Controller
Powering On an Oracle Storage Drive Enclosure DE3-24 or DE2-24 Disk Shelf
Powering On a Sun Disk Shelf
Controller.
Note:
All power cords must be disconnected to completely remove power from
the disk shelf.
Chapter 12
Powering Off a Disk Shelf
12-4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents