22
Device Description
3.6
Technical Data
3.6.1
Device Data
Table 9: Technical Data - Device
Width
High (from upper edge of DIN 35 rail)
Length
Weight
3.6.2
Supply
Table 10: Technical Data - Supply
Voltage Supply
Current consumption
Input voltage drop
Voltage via power jumper contacts
Transmitter supply
Current via power contacts
Power consumption P
Power loss P
Isolation
3.6.3
Communication
Table 11: Technical Data - Communication
Data width
(internal)
typ.
max.
max.
V
WAGO-I/O-SYSTEM 750
750-484 2 AI 4-20 mA HART Ex i
24 mm
64 mm
100 mm
approx. 105 g
Via system voltage terminal bus
(5 V DC) and power contacts (24 V DC)
25 mA
(I
< 28 mA):
meas
not linear, as protected against overload
U = 1.0 V + 300 Ω x I
24 V DC (Supply via Ex i-supply
module Uo = max. 27.3 V)
U
= 16.5 V at 20 mA
V
1000 mA
1.60 W (with slaves (20 mA))
0.62 W (without slaves)
300 VAC System/Supply
2 x 2 bytes data
or
2 x 2 bytes data + 2n x 4 bytes data
(n = number of dynamic variables)
or
2 x 2 bytes data + 6 bytes mailbox
V 1.2.0 HW-Version 04, SW-Version 03
meas