Installation; Unpacking And Assembly; Factory Setup - Rice Lake IQ plus 210 Installation Manual

Digital revolution scale software
Table of Contents

Advertisement

2.0

Installation

The IQ plus 210 digital weight indicator is designed for easy setup and installation. All models are pre-configured and weight
calibrated before shipment, with the load cell connected to the indicator. For simple, standalone scale applications, hardware
installation consists of attaching the indicator, mounting assembly, and bench scale, then leveling the scale.
The IQ plus 2100 is weight calibrated before shipment from the factory, but recalibration at the installation site is
Note
strongly recommended. Calibration by a certified scale technician is required for Legal-for-Trade applications.
2.1

Unpacking and Assembly

Immediately after unpacking, visually inspect the IQ plus 210 to ensure all components are included and undamaged. The
shipping carton should contain the indicator, the indicator mount (tilt stand) and a parts kit. If any parts were damaged in
shipment, notify Rice Lake Weighing Systems and the shipper immediately.
The parts kit contains the items listed below:
• Capacity label (PN 42350)
• One grounding clamp (PN 53075), external tooth lock washer, (PN 15133), and kep nut (PN 14626) for digital input or
serial cable shield grounding against the enclosure.
• Two wing knobs with nylon washers for attaching the indicator to the mounting assembly, four rubber tilt stand feet (for tilt
stand option) or bench scale feet, jam nuts, lock washers, and cap screws (for column and attachment bracket options).
To install, attach the mounting assembly to scale base, then assemble the indicator to the mounting assembly. Place the bench
scale in the desired location then lift off the scale platter and locate the bubble level. Adjust the corner feet until the scale is level
and all feet are in contact with the support surface. Tighten the jam nuts against the scale to lock-in the level adjustment.
Plug power cord into power outlet to begin weighing.
The supply cord serves as the power disconnect for the IQ plus 2100. The power outlet supplying the indicator
WARNING
must be installed near the unit and be easily accessible.
2.2

Factory Setup

The IQ plus 210 is pre-configured and weight calibrated at the factory before shipment. Table 2-1 lists the default graduations
and count-by configuration for each scale capacity.
5 lb
10 lb
25 lb
50 lb
100 lb
2.5 Kg
5 Kg
10 Kg
25 Kg
50 Kg
If scale configuration must be changed, see
page 19
for calibration instructions.
Scale Capacity
Count by
0.001 lb
0.002 lb
0.005 lb
0.01 lb
0.02 lb
0.0005 Kg
0.001 Kg
0.002 Kg
0.005 Kg
0.01 Kg
All capacities are pre-configured for 5000 graduations (GRADS
Note
parameter on CONFIG menu set to 5000).
Table 2-1. Default Scale Configurations
Section 3.0 on page 10
Configuration Parameters
DECPNT
888.888
1D
888.888
2D
888.888
5D
8888.88
1D
8888.88
2D
88.8888
5D
888.888
1D
888.888
2D
888.888
5D
8888.88
1D
for detailed configuration information. See
© Rice Lake Weighing Systems ● All Rights Reserved
Installation
DSPDIV
Section 4.0 on
3