Specifications - Rice Lake IQ plus 210 Installation Manual

Digital revolution scale software
Table of Contents

Advertisement

IQ plus 210 Installation Manual
6.6

Specifications

IQ plus 210 Indicator
Power
Line Voltages
115 or 230 VAC
Frequency
50 or 60 Hz
Power Consumption
70 mA @ 115 VAC (8W)
35 mA @ 230 VAC (8W)
Fusing
115 VAC
2 x 200 mA TR5 subminiature fuses
Wickmann Time-Lag 19374 Series
UL Listed, CSA Certified
230
VAC 2 x 100 mA TR5 subminiature fuses
Wickmann Time-Lag 19372 Series UL
Recognized, VDE Approved
Analog Specifications
Full Scale Input Signal
Up to 35 mV
Excitation Voltage
10 ± 0.25 VDC,
4 x 350Ω load cells
Analog Signal
Input Range
0.6 mV/V – 4.5 mV/V
Analog Signal
Sensitivity
0.3 µV/graduation minimum,
1.5 µV/grad recommended
Input Impedance
200 MΩ, typical
Display Resolution
10 000 dd
Input Sensitivity
155 nV per internal count
System Linearity
Within 0.01% of full scale
Calibration Method
Software, constants stored in
Common Mode
Voltage
–1.05 to +0.95 V, referred to earth
RFI Protection
Signal, excitation, and sense lines
protected by capacitor bypass
Digital Specifications
Digital Inputs
2 inputs, TTL or switch closure,
active-low
Digital Filter
Software selectable
Serial Communications
Serial Port
Full duplex RS-232; 9600, 4800,
2400, 1200 bps; 7 or 8 data bits;
even, odd, or no parity
Operator Interface
Display
6-digit LED display. 7-segment, .8 in
(20 mm) digits
LED annunciators
Negative value, center of zero, motion,
kg, g, lb, oz
Keypad
2 piezo switches
28
Visit our website
EEPROM
www.RiceLake.com
Environmental
Operating Temperature
–10 to +40°C (legal);
–10 to +50°C (industrial)
Storage Temperature
–25 to +70°C
Humidity
0–95% relative humidity
Altitude
2000 m (6500 ft) maximum
Enclosure
Enclosure Dimensions
9.5 in x 6 in x 2.75 in
24 cm x 15 cm x 7 cm
Weight
6.1 lb (2.8 Kg)
Rating/Material
NEMA 4X indoor use only, stainless steel
Approvals
NTEP
CoC Number
Accuracy Class
UL
File Number
®
Measurement Canada Approved
Approval
AM-5374
Accuracy Class
III/III HD
The IQ210 complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions:
• This device may not cause harmful interference.
• This device must accept any interference received,
including interference that may cause undesired
operation.
00-045
III/III L
E151461

Advertisement

Table of Contents
loading