Parameter Setting Commands - Rice Lake IQ plus 210 Installation Manual

Digital revolution scale software
Table of Contents

Advertisement

5.1.4

Parameter Setting Commands

Parameter setting commands allow you to display or change the current value for a particular configuration parameter (Tables
5-3 through 5-8).
Current configuration parameter settings can be displayed in either setup mode or normal mode using the following syntax:
command<ENTER>
Most parameter values only can be changed in setup mode. Use the following command syntax when changing parameter
values:
command=value<ENTER>
where
is a number or a parameter value. Use no spaces before or after the equal (=) sign. If you type an incorrect
value
command or value, the display reads
effect until you exit setup mode.
For example, to set the motion band parameter to 5, type the following:
MOTBAND=5D<ENTER>
Command
GRADS
Graduations
ZTRKBND
Zero track band
ZRANGE
Zero range
MOTBAND
Motion band
OVRLOAD
Overload
FILTER
Digital filtering
Command
PRI.DECPNT
Primary units decimal position
PRI.DSPDIV
Primary units display divisions
PRI.UNITS
Primary units
ALT.LB
Enable alternate units
ALT.KG
ALT.OZ
ALT.G
ALT.LBOZ
Command
WZERO
Zero calibration
WVAL
Test weight value
WSPAN
Span calibration
REZERO
Rezero
LC.CD
Set deadload count
LC.CW
Set span count
Command
EDP.BAUD
Serial port baud rate
EDP.BITS
Serial port data bits/parity
EDP.TERMIN
Serial port termination character
EDP.ECHO
Serial port echo command
PRNFREQ
Print frequency
. Changes to the parameters are saved as they are entered but typically do not take
??
Description
1–10 000
OFF, 0.5D, 1D, 3D
1.9%, 100%
1D, 2D, 3D, 5D, 10D, 20D, OFF
FS+2%, FS+1D, FS+9D, FS
1, 2, 4, 8, 16, 4RT, 8RT, 16RT
Table 5-3. CONFIG EDP Commands
Description
8.88888, 88.8888, 888.888, 8888.88, 88888.8, 888888, 888880 (88 88.8 or 888 88
in LB/OZ display mode)
1D, 2D, 5D
LB, KG, OZ, G, LB/OZ
ON, OFF
Table 5-4. FORMAT EDP Commands
Description
test_weight_value
value
value
Table 5-5. CALIBR EDP Commands
Description
1200, 2400, 4800, 9600
8NONE, 7EVEN, 7ODD
CR/LF, CR
OFF, ON
DEMAND, AUTO1, AUTO2, STREAM
Table 5-6. SERIAL EDP Commands
© Rice Lake Weighing Systems ● All Rights Reserved
EDP Commands
Values
Values
Values
Values
23

Advertisement

Table of Contents
loading

Table of Contents