Continuous Output (Stream) Format; Cable Specifications; Torque Specifications - Rice Lake IQ plus 210 Installation Manual

Digital revolution scale software
Table of Contents

Advertisement

6.3

Continuous Output (Stream) Format

Figure 6-1 shows the continuous output format sent to the IQ plus 210 EDP or printer port when the STREAM parameter
(SERIAL menu) is set to either EDP or PRN.
<STX> <POL> <wwwwwww> <UNIT> <G> <S>
ASCII 02
(decimal)
Polarity:
<Space> = Positive
<–> = Negative
<^> = Overload
<]> = Underrange
Weight data: 7 digits, right-justified, with
decimal point, leading zero suppression.
Overload =
Underrange =
Display overflow = OVERFL
6.4

Cable Specifications

6.5

Torque Specifications

^^^^^^^
] ] ] ] ] ] ]
Figure 6-1. Continuous Output Data Format
Connector
J1 and J2 (PN 153873)
16-28 AWG
J3 (PN 153883)
16-28 AWG
J13 (PN 181694)
16-24 AWG
DC Power (PN 15888)
12-24 AWG
Table 6-4. Recommended Wire Gauge Specifications
Cord Grip
PG9 (PN 15626)
PG11 (PN 68600)
Table 6-5. Cord Grip Specifications
Connector
Around cables
Cord grip to enclosure
Table 6-6. Cord Grip Specifications
G = Gross
L = pounds
K = kilogram
G = grams
O = ounces
<space> = lb/oz
Wire Gauge Range
Wire Strip Length
0.276'' (7 mm)
0.276'' (7 mm)
0.394'' (10 mm)
0.276'' (7 mm)
Diameter Range
0.138 - 0.315'' (3.5 - 8 mm)
0.197 - 0.394'' (5 - 10 mm)
Torque
22 in-lb
33 in-lb
© Rice Lake Weighing Systems ● All Rights Reserved
Appendix
<TERM>
<CR> <LF>
or <CR>
ASCII 13, 10
(decimal)
Status:
<space> = valid
I = Invalid
M = In motion
O = Over/under range
27

Advertisement

Table of Contents
loading

Table of Contents