Format Menu

CONFIG
XXXXXXX
FORMAT
PRIMAR
UNITS
DECPNT
LB
888.888
KG
8888.88
OZ
88888.8
G
888888
LB/OZ
888880
8.88888
88.8888
If UNITS=LB/OZ,
DECPNT selections are:
88 88.8
888 88
Parameter
Choices
PRIMAR
UNITS
DECPNT
DSPDIV
ALTUNT
LB
KG
OZ
G
LB/OZ
DECPNT
888.888
8888.88
88888.8
888888
888880
8.88888
88.8888
or
88 88.8
888 88
DSPDIV
1D
2D
5D
CALIBR
SERIAL
DIG IN
ALTUNT
DSPDIV
LB
1D
ON
2D
OFF
5D
Figure 3-7. Format Menu
FORMAT Menu
Level 2 submenus
Specifies the decimal position, display divisions, and units used for the primary units. See Level 3 submenu
parameter descriptions.
Specifies which alternate units can be displayed by pressing the UNITS. See Level 3 submenu parameter
descriptions.
NOTE: The LB/OZ setting is not a Legal-for-Trade setting.
Level 3 submenus
Primary Units (PRIMAR Parameter)
Decimal point location. Specifies the location of the decimal point or dummy zeroes in the primary unit display.
Value should be consistent with local legal requirements.
If LB/OZ is selected as the primary unit, DECPNT selections are 88 88.8 and 888 88.
Display divisions. Selects the minimum division size for the primary units displayed weight.
Table 3-3. Format Menu Parameters