Edp Command Configuration; Front Panel Configuration - Rice Lake IQ plus 210 Installation Manual

Digital revolution scale software
Table of Contents

Advertisement

3.1.2

EDP Command Configuration

The EDP command set can be used to configure the IQ plus 210 indicator using a personal computer, terminal, or remote
keyboard. Like Revolution, EDP command configuration sends commands to the indicator serial port; unlike Revolution, EDP
commands can be sent using any external device capable of sending ASCII characters over a serial connection.
EDP commands duplicate the functions available using the indicator front panel and provide some functions not otherwise
available. EDP commands can be used to simulate pressing front panel buttons, to configure the indicator, or to dump lists of
parameter settings. See
Section 5.0 on page 22
3.1.3

Front Panel Configuration

The IQ plus 210 indicator can be configured using a series of menus accessed through the indicator front panel when the
indicator is in setup mode. Table 3-1 summarizes the functions of each of the main menus.
Menu
CONFIG
Configuration
FORMAT
Format
CALIBR
Calibration
SERIAL
Serial
DIG IN
Digital Input
DEFLT
Default
VERS
Version
Neg
Zero
Motion
Front Panel Menu Navigation
The front panel buttons are used to navigate through the menus in setup mode (see
scrolls right (horizontally) on the same menu level; the
and serves as an Enter key for selecting parameter values within the menus.
for more information about using the EDP command set.
Configure grads, zero tracking, zero range, motion band, overload, and digital filtering parameters.
Set format of primary units, select alternate display units.
Calibrate indicator. See
Section 4.0 on page 19
Configure serial port.
Assign digital input functions.
Restore default configuration.
Display installed software version number.
Table 3-1. IQ plus 210 Menu Summary
D I G I T A L
ZERO
ZERO/ENTER
Move down in menu or
enter parameter value and
return to menu level above
Figure 3-2. Front Panel Key Functions in Setup Mode
ZERO
Menu Function
for calibration procedures.
W E I G H T
I N D I C A T O R
UNITS
UNITS/RIGHT
Move right in menu /
next parameter value
Figure
(
) button moves down (vertically) to different menu levels
ENTER
© Rice Lake Weighing Systems ● All Rights Reserved
Configuration
kg
g
lb
oz
3-2). The
(
) button
UNITS
RIGHT
11