Automatic Shutoff

Purpose:
Defines the maximum length of time the reader remains on when there is no
activity. When you do not use the reader for the length of time set for this
command, the reader automatically shuts off and goes into Suspend mode. The
reader also goes into a suspend state when you press
When you press
where it left off and all reader memory is saved.
Note: The timeout interval is reset when there is data in the transmit or receive buffer
of the radio, or when the radio is trying to recover a lost RF connection. Other factors
that may effect the interval being reset are input data from a scanner or keyboard, a low
battery condition, AC power connection, or an IRL receive command that has not
completed properly. When the timeout interval is reset, it must be counted down again.
Power Management Tip: You should use the Automatic Shutoff feature to preserve
the NiCad battery pack's power.
Note: If the reader is in a communications dock or a power supply is connected to the
reader through an optical link adapter, automatic shutoff is disabled.
Default:
1 minute
Syntax:
EZdata
Acceptable values for data are:
0M
1M-60M
15S
To set the timeout to 15 seconds, scan this bar code:
Scan:
Set Automatic Shutoff to 15 Seconds
*$+EZ15S*
*$+EZ15S*
Or:
To set the timeout in minutes:
1. Scan this bar code:
helconital
to turn the reader on again, the reader resumes exactly
Disabled (always on)
Shutoff time in minutes
15 seconds
Enter Accumulate Mode / Set Automatic Shutoff
*+/$+EZ*