Here are the parameters you can set for each communications protocol:
Multi-Drop protocol parameters
• Baud rate, parity, and data bits
• Transmit abort timeout
PC Standard protocol parameters
• Baud rate, parity, data bits, and stop bits
Point-to-Point protocol parameters
• Baud rate, parity, data bits, and stop bits
• Flow control
• Transmit abort timeout
Note: If you use User-Defined or Point-to-Point protocol, you should only set the
Timeout Delay command if the baud rate is 9600 or lower. You should disable Timeout
Delay if the baud rate for either of these protocols is set to 19200 or higher.
Polling Mode D protocol parameters
• Baud rate
• Flow control
• Transmit abort timeout
User-Defined protocol parameters
• Baud rate, parity, data bits, and stop bits
• Flow control and LRC
• Intercharacter delay, turnaround delay, and timeout delay
• Transmit abort timeout
• SOM, EOM (required)
• AFF, NEG, POL, REQ, RES, SEL
Note: You must set AFF and NEG together. If you set REQ, you must also set AFF
and NEG.