Note: If IPM_4M.EXE is not already loaded, the Internal Drive Reset After
Battery Change command and Reset Internal Drive After Battery Change
parameter have no effect on the reader.
To load IPM_4M.EXE into memory
• IPM_4M.EXE is loaded into memory when you boot the reader because this
command appears in the default AUTOEXEC.BAT file:
d:\ipm_4m.exe
IPM_4M.EXE is stored on drive D and the Application companion disk 3. If
the command is not in your AUTOEXEC.BAT file, type this command at
the DOS prompt:
d:\ipm_4m
Or scan this bar code:
*D/Z%LIPM%O4M*
*D:\IPM_4M*
To use the "Internal Drive Reset After Battery Change" command
• See "Internal Drive Reset After Battery Change" in Chapter 12.
To set the RESET INTERNAL DRIVE AFTER BATTERY CHANGE parameter
1. To start IC.EXE, type this command at the DOS prompt:
ic
Or scan this bar code:
*IC*
*IC*
2. Choose Power Mgmt from the Op menu. This screen appears.
Configuration
Oper/Power Mgmt
AUTO SHUTOFF:
INTERVAL:01
UNITS:MINUTES
RESET INTERNAL
DRIVE AFTER BATTERY
CHANGE:
Do Not Reset Card
OK
Cancel
BC
NF