8.18 Care

8.18.1 Safety instructions

CAUTION
Lack of or improper cleaning
Health hazard due to infections, damage to the product due to user error
► Clean the product at regular intervals.
► Water must not come into direct contact with the electronics, motor or batteries under any circumstances dur­
ing cleaning. Never use a water jet or high-pressure cleaning apparatus to clean the product.
► To avoid contamination with germs, clean seat cushions and back support upholstery whenever they get
soiled.
► Check the driving behaviour of the product after cleaning it.
INFORMATION
Piston rods do not require lubrication. They are maintenance-free.

8.18.2 Cleaning

Clean the product regularly depending on the degree of soiling and frequency of use, at least 1x per month:
Clean the control panel, battery charger, armrest and trim components with a damp cloth and mild cleaning
solution.
Use a dry brush to clean the seat and back upholstery as well as the seat cushion.
Use a damp plastic brush to clean the wheels and frame.
Do not use any aggressive cleaners, solvents or hard brushes etc.
Do not spray the product with a pressure washer.
Observe additional cleaning instructions:
Section "Lap belt": see Page 48
Section "Belts/belt systems": see Page 60
Section "Contoured pads": see Page 39

8.18.3 Disinfection

1) Thoroughly clean the pads before disinfecting.
2) Wipe all parts of the product with a disinfectant.
Important information about disinfecting
Only use colourless water-based disinfectants. Observe the instructions for use provided by the manufacturer.
Prior to disinfection, clean the seat and back padding, control panel and armrests.

9 Maintenance and repair

9.1 Maintenance

WARNING
Insufficient maintenance
Severe user injuries, damage to the product due to failure to observe maintenance intervals
► Only carry out the maintenance tasks described in this section. All other maintenance and service tasks may
only be carried out by qualified personnel.
► The functionality and operating safety of the product must be verified and a service performed at least
once per year.
► For users with a changing anatomy (for example body dimensions, weight) or users with a changing clinical
picture, have the product inspected, adjusted and serviced at least once every six months.