22
ELECTRIC ST ARTER
22.1
Checkin
the starter motor
Condition
The starter motor has been removed.
-
Connect the negative cable of a 12 volt power supply to the housing of the starter
motor. Connect the positive cable of the power supply briefly with the connec
O
tor
of the starter motor.
If the starter motor does not turn when the circuit is closed:
-
Change the starter motor.
303120-10
195