Chapter 7: Cscape Configuration; Overview; Cscape Status Bar - HORNER APG XL10 PRIME OCS User Manual

Table of Contents

Advertisement

CHAPTER 7:
7.1

Overview

EXL10/XL10 PRIME OCS hardware is programmed with a Windows based PC application called Cscape.
This application can be used to program, configure, monitor and debug all aspects of the EXL10/XL10
PRIME OCS unit. Please see the on-line help provided with Cscape for additional details.
7.2

Cscape Status Bar

When the EXL10/XL10 PRIME OCS is connected to a PC using Cscape software a Status Bar appears at
the bottom of the screen. The Cscape Status Bar can be used to determine if communications have been
established between the EXL10/XL10 PRIME OCS and the Cscape program. Components of the Cscape
Status Bar are explained below.
Message Line -
Equal Indicator – indicates whether the current program in Cscape is equal to the program stored in the
The contents of
Target Controller.
these messages are
context sensitive.
The Message line
can be empty.
Current User -
indicates who is logged (for
security purposes).
Controller Model - Network (Model Confirmation)
Controller Model indicates the controller model for which
the program in Cscape is configured.
Network indicates the type of network that the program in
Cscape expects to use (e.g., CsCAN).
(Model Confirmation) provides the following indications:
(Model=) - the actual Target Controller matches the
configured Controller Model and Network.
(Model Not=) – the actual Target Controller does not match
the configured Controller Model and Network.
(Model ?) – there may have been a change since the last
time the Target Controller was compared to the configured
Controller Model and Network.
J u l y 6 , 2 0 2 2
CSCAPE CONFIGURATION
If Equal, the program in Cscape is the same as the program stored in the Target Controller.
If Not Equal, the program in Cscape is not the same as the program stored in the Target Controller.
If Unknown, there may have been a change since the last time the program in Cscape was compared
to the Target Controller.
Figure 7.1 - Cscape Status Bar
MAN1029-10-EN_EXL10_XL10P_UM
Communications Status - indicates the current status of the
"pass through" Connector.
Local: xx – indicates the Network ID of the OCS to which the
Cscape program is physically connected through its serial port. It
can serve as a pass through device to other nodes on the
network.
Target: yy(R) – indicates the Network ID of the device with which
the Cscape program is exchanging data.
NOTE: The Local unit and Target unit can be the same unit
or they can be separate units.
The following are status indicators:
(R) – Running
(D) - Do I/O
(I) – Idle
(?) – Cscape is not communicating with the remote unit.
[no forces] – indicates no I/O has been forced.
File Modified Indicator - indicates that the
file in the selected window has been
modified but has not been saved.
P a g e 59 | 195