See
page 304
these features.
Automatic Configuration Update
When this feature is enabled, a reader and its linked Base Station can auto-
matically ensure they stay in sync with regard to application hardware and/
or configuration. See
$CBTCU01(CR)
Automatic Configuration Update = Enable
Copy Configuration to Scanner
Scan the following label to copy the current Base Station configuration to the
scanner. Use this method when the Auto Configuration Update feature is
disabled and you want a one-time configuration update to be performed on
the scanner.
Copy Configuration to Base Station
Scan the following label to copy the current scanner configuration to the
Base Station. Use this method when the Auto Configuration Update feature
is disabled and you want a one-time configuration update to be performed
on the Base Station.
Product Reference Guide
CONFIGURATION UPDATES
in "References" for detailed information and examples of
page 304
Do not scan an ENTER/EXIT PROGRAMMING MODE label with this bar
code.
CpyCfg2HH
Copy Configuration to Scanner
Cpycfg2Ba
Copy Configuration to Base Station
Do not scan an ENTER/EXIT PROGRAMMING MODE label with this bar
code.
Enter/Exit Programming Mode
for more information on this feature.
$CBTCU00(CR)
Automatic Configuration Update = Disable
DEFAULT
215