ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK charac-
ter from the host following label transmission. The selectable timeout range
is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A
selection of 0 disables the timeout.
To set this value:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments). Pad
3. Go to
4. Scan the bar code: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
This completes the procedure. See
set this feature.
Table 31. ACK NAK Timeout Value Setting Examples
STEP
ACTION
1
Desired Setting
2
Divide by 200
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ACK NAK TIMEOUT VALUE SETTING
Scan Two Characters From
5
Appendix D, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
276
the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
page 34
and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
pad, that represent the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
ming Mode.
EXAMPLES
200ms
01
'0' and '1'
Table 31
for some examples of how to
5200ms (5.2
1,000ms (1 sec.)
sec.)
05
26
'0' and '5'
'2' and '6'
PowerScan™ PD9530/PBT9500/PM9500
Appendix D, Key-
15,000ms (15 sec.)
75
'7' and '5'

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents