History Record - INFOSEC UPS SYSTEM ModT User Manual

Three phases modular ups solutions: 30 kva to 300 kva hv for 30 kva modules
Table of Contents

Advertisement

Warning! EEPROM Fail
Warning! Fan Lock
Warning! Line Phase Error
Warning! Bypass Phase Error
Warning! N Loss
Warning! Internal Initial Fail
Warning! Comm Syn Signal Fail
Warning! Comm. TRIG0 Fail
Warning! Redundancy Set Fail
Warning! Parallel Sys Config. Wrong
Warning! Maintenance Bypass
Warning! Battery Age Alert
Warning! Parallel Rack Cable Loosen
Warning! Parallel Rack Config. Wrong
Warning! Parallel Firmware Error
Warning! Battery Voltage Low
Warning! ID Conflict
Pre-Alarm! Line Voltage Fail
Pre-Alarm! Line Voltage Normal
Pre-Alarm! Line Frequency Unstable
Pre-Alarm! Line Frequency Normal
Pre-Alarm! Over Load
Pre-Alarm! Load Normal
Pre-Alarm! Load Unbalance

4.4 History Record

Table 4-13: Important setting changed
Item
No.
1
Setup! Model Name
3
Setup! Language
5
Setup! Adjust Time
7
Setup! System Installed Date
9
Setup! System Last Maintain Date
11
Setup! Battery Installed Date
13
Setup! Battery Last Maintain Date
15
Setup! Change Password
17
Setup! Baud Rate
19
Setup! Audible Alarm
21
Setup! Factory Reset
23
Setup! EEPROM Reset
25
Setup! EPO Function
INFOSEC UPS SYSTEM - 15, rue du Moulin - 44880 Sautron - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)240 94 29 51 - hotline@infosec.fr – 04 17 AA 59 201 06
EEPROM operation error
As stated.
As stated.
As stated.
Neutral loss
As stated.
Communicate Synchronization Signal Fail
Communicate Trigger signal fault
As stated.
Parallel System Configure error
Enter maintenance
Battery Life expiration
As stated.
Parallel Rack Configure error
Power module parallel firmware error
Battery voltage is too low.
Power module ID conflict.
Line voltage over range
Line voltage recovered to normal
Line frequency over range
Line frequency recovered to normal
Output Load over range
Output Load recovered to normal
Output Load unbalance
Description
Item
No.
Setup! Turn On Password
2
4
Setup! Change Turn On Password
6
Setup! Nominal Power Display
8
Setup! Output Voltage
10
Setup! Bypass Voltage Range
12
Setup! Bypass Frequency Range
14
Setup! Converter Mode
16
Setup! ECO Mode
18
Setup! Bypass Mode
20
Setup! Auto-Restart
22
Setup! Cold Start
24
Setup! Battery Mode Delay Time
26
Setup! Shutdown Restore Time
Description
81

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ModT and is the answer not in the manual?

Questions and answers