4. STARTUP
2) When regenerative brake option is used over 5kW
The lead of built-in regenerative brake resistor connected to P terminal and D terminal of TE1
terminal block should not be connected.
The generative brake option should be connected to P terminal and C terminal.
A twisted cable should be used when wiring is over 5m and under 10m. (Refer to Section 11.2)
3) When brake unit and power supply return converter are used over 5kW
The lead of built-in regenerative brake resistor connected to P terminal and D terminal of TE1
terminal block should not be connected.
Brake unit or power supply return converter should be connected to P terminal and N terminal. (Refer
www.DataSheet4U.com
to Section 11.3 and 11.4)
4) The power factor improving DC reactor should be connected across P
(2) I/O signal wiring
(a) The I/O signals should be connected correctly.
Use DO forced output to forcibly turn on/off the pins of the CN3 connector. This function can be used to
perform a wiring check. In this case, switch on the control circuit power supply only.
(b) 24VDC or higher voltage is not applied to the pins of connectors CN3.
(c) SD and DOCOM of connector CN3 is not shorted.
4.1.3 Surrounding environment
(1) Cable routing
(a) The wiring cables are free from excessive force.
(b) The encoder cable should not be used in excess of its flex life. (Refer to Section 11.4.)
(c) The connector part of the servo motor should not be strained.
(2) Environment
Signal cables and power cables are not shorted by wire offcuts, metallic dust or the like.
Power factor
Servo amplifier
improving DC
reactor
P
(Note)
P
Note. Always disconnect the wiring across P
Servo amplifier
CN3
DOCOM
SD
4 - 3
-P
. (Refer to Section 11.10.)