Selection Of Regenerative Brake Option; Using Absolute Position Detection System - Mitsubishi Electric MR-J3-10B Instruction Manual

General-purpose sscnet iii compatible
Hide thumbs Also See for MR-J3-10B:
Table of Contents

Advertisement

5. PARAMETERS

5.1.3 Selection of regenerative brake option

No.
Symbol
PA02 **REG Regenerative brake option
w w w . D a t a S h e e t 4 U . c o m
Set this parameter when using the regenerative brake option.

5.1.4 Using absolute position detection system

No.
Symbol
PA03
*ABS
Set this parameter when using the absolute position detection system in the position control mode.
Parameter
POINT
This parameter value and switch power off once, then switch it on again to
make that parameter setting valid.
Wrong setting may cause the regenerative brake option to burn.
If the regenerative brake option selected is not for use with the servo
amplifier, parameter error (37) occurs.
Parameter No. PA02
0 0
Selection of regenerative brake option
00: Regenerative brake option is not used
For MR-J3-10B, regenerative brake resistor is not used.
For MR-J3-20B or more, built-in regenerative brake resistor is used.
01: FR-BU FR-RC
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50
08: MR-RB31
09: MR-RB51
Parameter
Absolute position detection system
POINT
This parameter is made valid when power is switched off, then on after
setting, or when the controller reset has been performed.
This parameter cannot be used in the speed control mode.
Parameter No. PA03
0 0 0
Selection of absolute position detection system (refer to Chapter 12)
0: Used in incremental system
1: Used in absolute position detection system
Name
Name
5 - 3
Initial Value
Unit
Setting Range
0000h
Refer to the text.
Initial Value
Unit
Setting Range
0000h
Refer to the text.

Advertisement

Table of Contents
loading

Table of Contents