1. FUNCTIONS AND CONFIGURATION

1.8 Configuration including auxiliary equipment

(1) MR-J3-100B or less
(a) For 3-phase 200V to 230VAC or 1-phase 230VAC
(Note3)
3-phase 200V
www.DataSheet4U.com
to 230VAC power
supply or
1-phase 230VAC
power supply
No-fuse breaker
(NFB) or fuse
Magnetic
contactor
(MC)
Line noise
filter
(FR-BLF01)
(Note2)
Power factor
improving DC
reactor
(FR-BEL)
Note 1. The battery unit(option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used.
3. A 1-phase 230VAC power supply may be used with the servo amplifier of MR-J3-70B or less.
POINT
Equipment other than the servo amplifier and servo motor are optional or
recommended products.
R S T
(Note2)
L1
L2
L3
P1
P2
P
C
Regenerative brake
option
L11
L21
CN5
Servo amplifier
CN3
CN1A
CN1B
U
V
W
CN2
CN4
(Note1)
Battery unit
MR-J3BAT
1 - 14
Personal
MR Configurator
computer
(Servo
configuration
Junction terminal
block
Servo system
controller or Front axis
servo amplifier
Rear servo amplifier
CN1A or Cap